Generic InterBus
Module Identifier
Codes
InterBus device manufacturers embed an identifier code in their network slave
modules in conformance with InterBus standards. The code identifies a device by
its I/O type but not its specific model or name.
I/OBus recognizes the InterBus identifier codes provided below and allows you to
I/O Map devices that use these codes. However, you cannot use the module zoom
screens to define the parameters for these InterBus modules.
Continued on next page
Identifier Code I/O Type
0101_IOBUS One-word discrete output
0102_IOBUS One-word discrete input
0103_IOBUS One-word discrete bidirectional
0201_IOBUS Two-word discrete output
0202_IOBUS Two-word discrete input
0203_IOBUS Two-word discrete bidirectional
0231_IOBUS Two-word analog output
0232_IOBUS Two-word analog input
0233_IOBUS Two-word analog bidirectional
0301_IOBUS Three-word discrete output
0302_IOBUS Three-word discrete input
0303_IOBUS Three-word discrete bidirectional
0331_IOBUS Three-word analog output
0332_IOBUS Three-word analog input
0333_IOBUS Three-word analog bidirectional
0401_IOBUS Four-word discrete output
0402_IOBUS Four-word discrete input
0403_IOBUS Four-word discrete bidirectional
0431_IOBUS Four-word analog output
0432_IOBUS Four-word analog input
0433_IOBUS Four-word analog bidirectional